What exactly is the difference between a surge protector and a fuse? Can a fuse protect the electronic devices from lightning instead of surge protector?
Last Updated: 21.06.2025 01:42

If the nominal power is 4,000 watts then the current at 230volts is 16 amps.
eight
Here is a simplified AC power diagram.
Northern Lights Alert: 8 States May See Aurora Borealis Monday Night - Forbes
One
These devices are installed between the “hot” and “neutral” and protective ground.
OK, this is Mohan Rajaratnam’s definition of a Surge suppressor.
Do women wear undies under leggings?
This is an electronic circuit designed to clamp voltages so that the Voltage Potential that appears at the outlet is never going to exceed the nominal value.
This is where this question deviates from being a 'generic' question, and becomes more specific.
What does a fuse do?
Why do some people dislike Gilmore girls?
But… the neutral is now “floating” because of the 1 ohm resistance.
(Dc diagram shown, AC is similar).
So, the voltage could go up to 500 volts, and the fuse will not open up.
One is “what exactly is in a ‘surge protector’ ? ”
“ A surge suppressor is the one which is connected at the input supply so that when there is a sudden change voltage it bypasses thereby protecting the (circuit) and electronic components”
a photo is worth a thousand words.
Can the fuse protect the electronic devices from lightning instead of a surge protector.
Would individual surge supressors have save this equipment? most likely, since the surge supressor would take the jolt instead of the electronic components.
So combined with a device called a MOV or Metal-oxide-resistor, then forms the 3rd part of a “surge suppressor “.
Why can’t my wife just accept the fact that I’m going to cheat?
Because the load is inductive, the current lags the voltage.(by a bit).
But during the surge, the fuse will not blow if it is a longer duration and lower value )10 to 50%).
Mohan forgets that a fuse is a one-time device, and needs to be replaced if it is tripped.
nine
Now when you have a certain ac resistance, then a current flows in a loop.
There is no harm in having the surge suppressor along with the fuse in the circuit. The fuse will not open up until the current melts the link. This will take time, and in the interim, that jolt will get transmitted into the power supplies.
How does a man look at you when he is in love?
2024–10–14 [Omar Gharbi Omar Gharbi ]
At one ohm, the resistor has a maximum of 1 watt power.
“ … to protect building, lightning arrestor, is provided above building and directly connected to earth.”
This one hit behind the barn.
I post the exact comment here.
The bolt then partially travels down the line to your home.
What is your worst experience in life?
First Sentence:
Lightning arrestor is a spark-gap device, and can be installed anywhere. What is important, is that the wire is thick enough to withstand the lightning bolt and conduct the energy away from the building.
what exactly is a ‘surge’ protector?
Why do so many people like life?
A fuse is a non-resetable over current circuit protector.
The other is “what does a “fuse” do?”
It’s been three xxx five werks, and there has been no response to my follow on query on his Commment to my answer.
Can you DM your uncle’s wife for a video?
(There is no concept of polarity, in the loop because the current changes direction 100 to 120 times a second (power frequency).
The third is lightning and “how it gets conducted into a home.”
Fuses, on their own, then operate much slower than the MOV variable resistance, during the lightning strike.
The MOV will conduct when the voltage exceeds 50% of line voltage.
What is lightning?
These are simplified answers to the original question, and does not change anything I wrote above.
so, the loop of wire then, when put together with another loop reduces the ‘noise’ on a power line.
Edit 2024–10.
[old diagram got deleted by accident]
“ A fuse is a device which protects the (circuit) against overload and short circuit.”
This is a high voltage low current spike that comes down the line because of the power poles being struck, and the voltage suppressors activating on the primary side of the transformer.
[image of Common-mode choke]
He then describes Rainy Season and Lightning.
Is the question then , "why buy a surge supressor, if the fuse alone protects the electronic circuits from a lightning bolt?".
This is where the MOV conducts again, and dissipated the energy.
2024–10–11 [Bobby Sanchez Bobby Sanchez ].
the problem then depends on "how fast does the fuse operate?".
This is the picture of an electronic coil of wire wound around a core of magnetic material.
P = e* I, so since I is 16 amps, then the voltage dropped is 1/16 volt or 0.0650 volts.
Once the voltage goes over 0.0650 volts, then this fact can be used to amplify the difference, and turn the circuit breaker off , furthur down the line. Essentially that is what a RCD/GFCI does, it compares the incoming current, to the outgoing current, and if the difference between the two currents is over 5mA, then it trips the circuit breaker.
but this device (an Inductor) … impedes the rapid changes in the current.
So, it’s possible that these devices from Trip Lite have addition suppression devices, these ones seem to be sturdy.
He then asserts :
but I think this circuit , shows a few more pieces.
This is 'the assistant's answer'
For this case there are devices called Metal oxide varistors (MOV).
He then describes the function of a fuse.
At the secondary, it is 1000 times less.)turns ratio). If it gets hit with a 100,000 volt bolt of lightning then the voltage arrestors conduct and clamp the voltage down to line voltage, ( but a small amount leaks down the line). This is the problem.
It seems Mohan does not understand the difference between a comment and an Answer.
A circuit breaker is similar, but is resettable.
2024–09–27 [ Mohan Rajaratnam Mohan Rajaratnam ] . Thinks you can get free electricity from nothing : Mohan Rajaratnam's answer to Is it possible to generate free electricity at home using a magnet or other low-cost methods? If so, how does it work?
When the current is 200% of the rated value , it will “go open” (the link metal melts) and protect the device.
An AC voltage/ current source, and an ac inductive load.
Upvotes:
2024–10–10[John johnson John Johnson ]
Barnstars:
This device then solves the entire problem.
2024–10–00 [ Ammar Mahdi ] Ammar Mahdi
2024–10–16 [ OO OLAOYE OYEBODE ]
At least they know the answer if they wanted it.
There are three different concepts here that are getting confused.
And this is the problem alone. Is the power supply in the equipmemt designed with a lightning strike in mind? Some yes, others, no.
There are two important concepts here.
It also is a device that limits the change in current flow.
so, what happens?
2024–10–11 [Victor Olarewsju Victor Olarewaju ]
This is a photo where a lightning bolt took out a home's complete mains distribution box, and a lot of electronic gear as well.
But it can get overloaded, and no longer works.
In schematic diagrams this is the symbol for a fuse: